Keypad 5 Device Address 20
1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800
2) enter *193
3) Enter Desired Field (Input guide will be posted below this)
Inputs:
VISTA-20P:
Enter partition where
0 = keypad disabled
1-3 = part. no. (3 = com)
VISTA-15P:
Section 1:
1 = enable
0 = disable Sound:
Section2:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime beeps
4) enter *99 to exit programming
Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P