Phone Line Monitor Enable
1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800
2) enter *92
3) Enter Desired Field (Input guide will be posted below this)
Inputs:
Entry 1:
0 = disabled
1-15 = 1 min - 15 min
#+10 = 10 min
#+11 = 11 min
#+12 = 12 min
#+13 = 13 min
#+14 = 14 min
#+15 = 15 min
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as “1”, plus programmed output device STARTS. If either partition is armed, external sounder activates also.
NOTE: Output Device must either be programmed to be STOPPED in field ✱80 or STOPPED by Code + # + 8 + output number.
4) enter *99 to exit programming
Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P
Programming Manual For More Information:
https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf
GeoArm can assist in changing the installer code upon activation.