How to Adjust the SiXGB Sensitivity Range
To adjust the Honeywell SiXGB sensitivity range from the Lyric Controller home screen select Security > Tools > enter the installer code "default installer code is 4112" > Program > Zones > Start on the right side > Pull the battery tab out of the SiXGB > Select Edit for this device > Program to your liking > Select Down arrow > Adjust the sensitivity > Save > back out to the home screen.
The maximum range for the SixGB microphone is 25ft and can be altered via Lyric panel programming.
High (default) - 15-25ft
Medium - 10-15ft
Low - 5-10ft Lowest - 0-5ft
Range must be verified by FG-701 simulator.