Alarm Bell Timeout
1) Enter Installer Code on the panel while disarmed (Default 4112) + 800
2) You Will now see 20 INSTALLER CODE if that was the correct installer code.
3) Press *33
UL installations: must be set for a minimum of 4 min (option 1)
0 = No timeout
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
4) Press *99 After the screen updates to the next field to exit the programming
Note: GeoArm can change the installer code upon activation