Entry Delay 1
1) Enter Installer Code on the panel while disarmed (Default 4112) + 800
2) You Will now see 20 INSTALLER CODE if that was the correct installer code.
3) Press *35
UL installations: The Entry Delay must be set for a maximum of 45 seconds
SIA The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1,
entered in Field ✻35, and the burglary abort window, entered in Field ✻50, should
not exceed 1 minute.
00-99 = entry delay in seconds
4) Press *99 After the screen updates to the next field to exit the programming
Note: GeoArm can change the installer code upon activation