Programmable Tone Generation Time

1) Enter Installer Code on the panel while disarmed (Default 4112) + 800

2) You Will now see 20 INSTALLER CODE if that was the correct installer code.

3) Press *78

This field is used to set the time delay between when a connection is established on a
Radio (digital communication with voice capabilities) session to when the 2100 Hz
“training” tone is terminated. Enter any digit between 00 and 99.

Note: This field only applies when a GSMVL radio is installed in the control. Otherwise, enter “00” to
disable.


SELECTIONS
00 = Disabled
01-09 = 100-900 ms
10-99 = 1.0 – 9.9 secs.

4) Press *99 After the screen updates to the next field to exit programming

Note: GeoArm can change the installer code upon activation

Follow Install manual for more information: 
https://turbifycdn.com/ty/cdn/yhst-51756635596032/l3000-honeywell-lynx-plus-wireless-control-panel-installation-and-setup-guide.pdf

l3000-resideo-honeywell-home-lynx-plus-wireless-control-panel-10