Programming Fields List

*20 Installer Code
*21 Quick Arm
*22 Keypad BackLight
*23 Forced Bypass
*24 RF House ID Code
*25 x10 House Code
*26 Chime by Zone
*27 Clock Display
*29 Day Ligh Savings Time Start/End Month
*30 Day Light Savings Time Start/End Month
*31 Single Alarm SND
*32 Sounder Timeout
*33 Alarm Bell Time Out
*34 Exit Delay 
*35 Entry Delay 1
*36 Entry Delay 2
*37 Audible Exit Warning/Quit Exit
*38 Confirmation for Arming Ding
*39 Power Up in Previous State and Cross Timer Zone
*40 PABX Access Code
*41 Primary Phone Number
*42 Secondary Phone Number
*43 Primary Subscriber ID
*44 Secondary Subscriber ID
*46 Follow Me Reminder Phone Number
*47 Phone System Select
*48 Report Format for Primary/Secondary
*49 Split/Dual Reporting
*50 Burglary Dial Delay
*51 Periodic Test Report
*52 First Test Report offset
*53 sescoa Radionics Select
*54 Lack Of Usage
*55 Report Channels
*56 Enhanced Zone Programming Mode
*57 False Alarm Options
*58 RF Jam Detection
*59 Exit Error Report Code
*60 Trouble Report Code
*61 Bypass Report Code
*62 AC Loss Report Code
*63 Low Battery Report Code
*64 Test Report Code
*65 Open Report Code
*66 Away/Stay Report Code
*67 RF Transmitter Low Battery Report Code
*68 Cancel Report Code 
*69 Recent Closing Report Code
*70 Alarm Restore Report Code
*71 Trouble Restore Report Code
*72 Bypass Restore Report Code
*73 AC Restore Report Code
*74 Low Battery Restore Report Code
*75 Rf Transmitter Low Battery Report Code
*76 Test Restore Report 
*77 Dynamic Signal Delay / Dyamic Signaling Priority
*78 Programmable Tone Generation Time
*80 Device Programming Menu Mode
*81 Zone List Menu Mode
*83 Enhanced Sequential Mode
*84 Assign Zone Voice Descriptors 
*85 Record Custom Voice Descriptors
*86 Multi Mode Email Notification
*87 AUX Function/1-Button Paging 
*88 Pager Characters
*89 Event Log 80% Full Report Code
*90 Event Logging Options
*91 Audio Alarm Verification (AAV)/ Remote Phone Control
*92 Swinger Shutdown 
*93 Swinger Shutdown
*94 Flexible Callback
*95 Download Call Back Phone Number
*96 Initialize Download ID and Subscriber Account Number for Downloading
 Entering *96 resets all subscriber account numbers and CSID in preparation for an initial download. 
*97 To load the factory defaults, enter *97, then press number 1, 2, 3, or 4 to select from default tables 1-4,
or press “0” if you are not selecting a default table. Refer to the Programming Default Tables section of this
manual to view the tables
*98 Exits program mode and inhibits re-entry into the Expert or Voice Prompt Programming modes using
the Installer Code
*99 Exits program mode but allows re-entry into the Expert Program mode using Installer Code (4112) +
800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888.