What is the Lyric Controller Go No - Go Test

The Honeywell Lyric Controller has a test mode call the Go No Go Test. The Lyric controller 5800RF Go/No Go tests will verify adequate 5800RF signal strength from the proposed transmitter location, and allow you to reorient or relocate transmitters if necessary, before mounting the transmitters permanently.

This mode is similar to the transmitter Walk Test mode, except that the wireless receiver gain is reduced. This will enable you to make sure that the RF signal from each transmitter is received with sufficient signal amplitude when the system is in the normal operating mode.

To perform a Go-No-Go-Test : 

1. Press Tools, Installer Code, Test, Go-No-Go Test.

2. Once you have placed transmitters in their desired locations and the approximate length of wire to be run to sensors is connected to the transmitter's screw terminals (if used), fault each transmitter. Do not conduct this test with your hand wrapped around the transmitter, as this will cause inaccurate results

Note: On button type transmitters whose buttons have been set to Arm AWAY, Arm STAY, or Disarm, pressing a button will take the system out of the Go/No Go Test mode and cause that action.

a. The keypad will beep three times to indicate signal reception and display the appropriate zone.

b. If the keypad does not beep, reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required.

4. If each transmitter produces the proper keypad response when it is faulted, you can then permanently mount each of the transmitters according to the instructions provided with them.

5. Exit the Go/No Go Test mode by entering code. 

lcp500-l-resideo-honeywell-home-lyric-controller-wireless-touchscreen-control-panel-1