What is the Lyric Controller Power up Procedure
To power up a Honeywell Lyric controller it must have the battery plugged in first, then apply Transformer power.
2. CHECK THE DISTANCE OF THE TRANSFORMER WIRE! When wiring the Transformer, the wire should never be further than 20 feet on 18ga wire. When using smaller wire, 20ga wire 13 feet, and 22ga wire 8 feet.
3. Check the polarity of the transformer. It is a DC transformer.
4. After power up the home screen will be displayed during its boot up sequence and with “System Standby…” at the top for 2 minutes.
5. The Wi-Fi enrollment screen will be displayed upon boot-up for a defaulted Controller or a Controller that has not been associated with AlarmNet 360. Select, “Scan Access Points” to find available broadcasting networks. Select the Network to join.