Keypad 7 Device Address 22

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *195

3) Enter Desired Field (Input guide will be posted below this)

Inputs:

VISTA-20P:
Enter partition where

0 = keypad disabled
1-3 = part. no. (3 = com) 


VISTA-15P: 

Section 1:
1 = enable
0 = disable Sound: 

Section2:
0 = no suppression
 1 = suppress arm/disarm and E/E beeps
 2 = Suppress chime beeps only
 3 = suppress arm/disarm, E/E, and chime beeps

4) enter *99 to exit programming

Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information:

https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf

GeoArm can assist in changing the installer code upon activation.