Zone Programming Menu Mode - Programming a New Zone - Adding a New Sensor

vista-20p-honeywell-8-zone-alarm-control-panel-93

For each of the following prompts, make the desired entry, followed by the [∗] key to accept the entry.
Refer to the Installation and Setup Guide for detailed explanations for each prompt

1) enter Installer Code into a PROGRAMMING KEYPAD ONLY (Default 4112) + 800

2) enter *56

3) Enter Desired Field (Input guide will be posted below this)

Section 1: SET TO CONFIRM?

0 = no; 1 = yes (See XMIT TO CONFIRM prompt later in this section.) We recommend that you confirm the programming of every transmitter.

Section 2: Enter Zone Number

01-64, 91, 92, 95, 96, 99
To quit, enter 00 to quit (returns to data field mode).

Section 3:  Zone Type

00 = Not used 
01 = Entry/exit #1 
02 = Entry/exit #2
03 = Perimeter 
04 = Interior Follower 
05 = Trouble Day/Alarm Night 
06 = 24-Hr Silent 
07 = 24-Hr Audible 
08 = 24-Hr Aux 
 09 = Fire 
10 = Interior w/Delay 
12 = Monitor Zone 
14 = Carbon Monoxide 
16 = Fire w/Verify 
24 = Silent Burglary
23 = No Alarm Resp
20 = Arm–STAY*
21 = Arm–AWAY*
22 = Disarm*
77 = Keyswitch
81 = AAV Monitor


Section 4: PARTITION (VISTA-20P)

1, 2, or 3-common 

Section 5: REPORT CODE

1-9
10 for 0
11 for B
12 for C
13 for D
14 for E
15 for F

Note: For Contact ID®, enter any non-zero entry as the first digit to
enable reporting for this zone.
To disable the report code for this zone, enter 00. 


Section 5: HARDWIRE TYPE


Appears only for zones 02-08. 
Zone 1 is automatically set for EOL operation. Enter the desired hardwire type:
0 = EOL
1 = NC
2 = NO
3 = zone doubling (ZD) VISTA-20P only
4 = doublebalanced (DB) VISTA-20P only

For hardwired zones 01-08. 
Enter the response time for this zone:
0 = 10mSec; 1 = 350mSec; 2 = 700mSec;
3 = 1.2 secs (see field ∗174).

NOTE: If zone doubling is being used, the response time selected for zones 02-08 automatically applies to each zone’s associated doubled zone


Section 6: INPUT TYPE

Skipped for zones 2-8, and for zones 10-16 if zone-doubling enabled. 
Enter the input type: 

2 = AW (Aux wired zone)
3 = RF (supervised RF)
4 = UR (unsupervised RF)
5 = BR (unsupervised button type)

NOTE: To change the input type of a previously programmed wireless device to a wired zone, you must first delete the transmitter’s serial number. 


Section 7: INPUT S/N 

1. 
a. Transmit two open/close sequences (for button-type transmitters, press and release the button twice, waiting about 4 seconds before pressing the button the second time).
 OR
 b. Manually enter the 7-digit serial number printed on the label of the transmitter. Press the [∗] key to move to the “L” position, then enter the loop number.

 Use the [A] (Advance) and [B] (Back) keys to move the cursor forward and back within the screen. Pressing the [C] (Copy) key will insert the previously enrolled serial number, if desired (used when programming a transmitter with several input loops).

Note:
To delete an existing serial number, enter 0 in the loop number field. The serial number will change to 0's. If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display

2. Press [∗] to continue. The system now checks for a duplicate serial/loop number.  If no duplicate is found, the display shows the serial number and loop number.

3. Press [∗] to continue to confirmation screen.


Section 8: XMIT TO confirm 

Appears if you answered “Yes” at the “Set to Confirm” prompt. Activate the loop input or button that corresponds to this zone. Press [∗] to continue. If the serial/loop number transmitted does not match the serial number entered, a display showing the entered and the received serial/loop numbers appears. If so, activate the loop input or button on the transmitter once again. If a match is not obtained, press the [#] key twice and then enter (or transmit) the correct serial number.

Press [∗] to continue


If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and a summary display will appear, showing that zone's programming. An “s” indicates that a transmitter’s serial number has been enrolled.

Press [∗] to accept the zone information and continue.

Section 9: PROGRAM ALPHA

Press 1 if you want to program descriptors for the zone now, and refer to the *82 Descriptor Programming section for procedure article.

To program descriptors later
enter 0 to skip

Press [∗] to continue to the Enter Zone Number prompt.

4) enter *99 to exit programming

Note:
The Vista 15P does not have partitions, any fields dealing with partitions will not be available on the Vista 15P

Programming Manual For More Information:

https://turbifycdn.com/ty/cdn/yhst-51756635596032/honeywell-vista-20p-control-panel-programming-guide.pdf

GeoArm can assist in changing the installer code upon activation.